Результаты исследований: Вклад в журнал › Статья › Рецензирование
Результаты исследований: Вклад в журнал › Статья › Рецензирование
}
TY - JOUR
T1 - Voltammetric Determination of Measles Virus Antibodies Using a Glassy Carbon Electrode Modified with 2-Propargyltio-6-nitro-7-hydroxy-4H-1,2,4-triazolo-4,7-dihydro[5,1-c]-1,2,4-triazine
AU - Medvedeva, M.
AU - Mazur, A.
AU - Svalova, T.
AU - Balin, I.
AU - Rusinov, V.
AU - Matern, A.
AU - Kozitsina, A.
N1 - This work was supported by the Russian Science Foundation, project no. 20-13-00142-P.
PY - 2023/12/1
Y1 - 2023/12/1
N2 - A method is proposed for the voltammetric determination of measles antibodies using a glassy carbon electrode modified with 2-propargylthio-6-nitro-7-hydroxy-4H-1,2,4-triazolo-4,7-dihydro[5,1-c]-1,2,4-triazine. An analytical signal was generated using a synthesized original compound attached to the surface of carboxylated carbon nanotubes through a thioline reaction and acted as a cross-linker for the immobilization of a bioreceptor, the measles virus antigen. We selected optimal working conditions for determining measles antibodies: signal recording mode, incubation time, temperature, pH of measurements, and concentration of the immobilized antigen. A calibration dependence I* (%) = –(1.5 ± 0.7)log с(IU/mL) + (29 ± 2) (R2 = 0.9653) was linear in the concentration range of measles antibodies 0.1–5.0 IU/mL. The limit of detection equal to 0.17 IU/mL, calculated using the 3σ test, ensures the use of the proposed method for the rapid analysis of biological fluids.
AB - A method is proposed for the voltammetric determination of measles antibodies using a glassy carbon electrode modified with 2-propargylthio-6-nitro-7-hydroxy-4H-1,2,4-triazolo-4,7-dihydro[5,1-c]-1,2,4-triazine. An analytical signal was generated using a synthesized original compound attached to the surface of carboxylated carbon nanotubes through a thioline reaction and acted as a cross-linker for the immobilization of a bioreceptor, the measles virus antigen. We selected optimal working conditions for determining measles antibodies: signal recording mode, incubation time, temperature, pH of measurements, and concentration of the immobilized antigen. A calibration dependence I* (%) = –(1.5 ± 0.7)log с(IU/mL) + (29 ± 2) (R2 = 0.9653) was linear in the concentration range of measles antibodies 0.1–5.0 IU/mL. The limit of detection equal to 0.17 IU/mL, calculated using the 3σ test, ensures the use of the proposed method for the rapid analysis of biological fluids.
UR - http://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=85183665984
UR - https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=tsmetrics&SrcApp=tsm_test&DestApp=WOS_CPL&DestLinkType=FullRecord&KeyUT=001156728900008
U2 - 10.1134/S1061934823120109
DO - 10.1134/S1061934823120109
M3 - Article
VL - 78
SP - 1694
EP - 1700
JO - Journal of Analytical Chemistry
JF - Journal of Analytical Chemistry
SN - 1061-9348
IS - 12
ER -
ID: 52294948