Результаты исследований: Вклад в журнал › Статья › Рецензирование
Результаты исследований: Вклад в журнал › Статья › Рецензирование
}
TY - JOUR
T1 - Tempered glass as a thermoluminescent medium for retrospective dosimetry
AU - Muslima, Umme
AU - Khandaker, Mayeen Uddin
AU - Lam, S. E.
AU - Nawi, S. N. Mat
AU - Sani, S. F. Abdul
AU - Osman, Hamid
AU - Hanfi, Mohamed Y.
AU - Sayyed, M. I.
AU - Bradley, D. A.
N1 - This work was supported by Sunway University Research Grant: GRTIN-IGS(02)-CAPRT-06-2023.
PY - 2024/4/1
Y1 - 2024/4/1
N2 - Globally, the use of nuclear facilities and the potential risks associated with the dispersal of ionizing radiation due to natural disasters or technical failures are on the rise. These risks can have severe consequences for the environment and all living organisms, particularly humans. There is currently no practical method available to accurately estimate the radiation doses received by the surrounding areas and individuals in such situations. To address this issue, retrospective dosimetry can be employed to estimate the actual radiation dose, followed by the implementation of remediation techniques. Considering this need, tempered glass, which is commonly used as a screen protector for smartphones by the general public, has been identified as a promising medium for retrospective dosimetry. The present study aimed to investigate the thermoluminescence (TL) properties of six different types of tempered glass subjected to 60Co gamma rays, specifically examining the TL dose response, linearity, repeatability, and fading. Among the various glass samples tested, HD anti-peep tempered glass demonstrates a highly linear dose-response and the greatest dose sensitivity within the examined dose range of 2–50 Gy. Additionally, the HD anti-peep tempered glass exhibits minimal loss of TL yield (∼23%) at 28 days post-irradiation, making it particularly suitable for use as a retrospective dosimeter.
AB - Globally, the use of nuclear facilities and the potential risks associated with the dispersal of ionizing radiation due to natural disasters or technical failures are on the rise. These risks can have severe consequences for the environment and all living organisms, particularly humans. There is currently no practical method available to accurately estimate the radiation doses received by the surrounding areas and individuals in such situations. To address this issue, retrospective dosimetry can be employed to estimate the actual radiation dose, followed by the implementation of remediation techniques. Considering this need, tempered glass, which is commonly used as a screen protector for smartphones by the general public, has been identified as a promising medium for retrospective dosimetry. The present study aimed to investigate the thermoluminescence (TL) properties of six different types of tempered glass subjected to 60Co gamma rays, specifically examining the TL dose response, linearity, repeatability, and fading. Among the various glass samples tested, HD anti-peep tempered glass demonstrates a highly linear dose-response and the greatest dose sensitivity within the examined dose range of 2–50 Gy. Additionally, the HD anti-peep tempered glass exhibits minimal loss of TL yield (∼23%) at 28 days post-irradiation, making it particularly suitable for use as a retrospective dosimeter.
UR - http://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=85182887240
UR - https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=tsmetrics&SrcApp=tsm_test&DestApp=WOS_CPL&DestLinkType=FullRecord&KeyUT=001162770900001
U2 - 10.1016/j.radphyschem.2024.111534
DO - 10.1016/j.radphyschem.2024.111534
M3 - Article
VL - 217
JO - Radiation Physics and Chemistry
JF - Radiation Physics and Chemistry
SN - 0969-806X
M1 - 111534
ER -
ID: 52294343