Ссылки

DOI

Results from statistical simulation of damages to the tube systems of the condensers and high-pressure heaters used in steam-turbine units are presented. The flow of failures of high-pressure heaters is described, using which their failure rates are estimated, and data are given that allow measures to be recommended on improving the system of maintenance activities for these apparatuses.
Язык оригиналаАнглийский
Страницы (с-по)664-671
Число страниц8
ЖурналThermal Engineering
Том54
Номер выпуска8
DOI
СостояниеОпубликовано - 1 авг. 2007

    Предметные области ASJC Scopus

  • Nuclear Energy and Engineering
  • Energy Engineering and Power Technology

ID: 42096768