Standard

Mass spectrometry determination of the isotopic composition of uranium hexafluoride. / Saprygin, A. V.; Elistratov, O. V.; Kalashnikov, V. A. и др.
в: Journal of Analytical Chemistry, Том 66, № 14, 2011, стр. 1385-1391.

Результаты исследований: Вклад в журналСтатьяРецензирование

Harvard

Saprygin, AV, Elistratov, OV, Kalashnikov, VA, Kulik, IS & Rodichev, IA 2011, 'Mass spectrometry determination of the isotopic composition of uranium hexafluoride', Journal of Analytical Chemistry, Том. 66, № 14, стр. 1385-1391. https://doi.org/10.1134/S106193481114019X

APA

Saprygin, A. V., Elistratov, O. V., Kalashnikov, V. A., Kulik, I. S., & Rodichev, I. A. (2011). Mass spectrometry determination of the isotopic composition of uranium hexafluoride. Journal of Analytical Chemistry, 66(14), 1385-1391. https://doi.org/10.1134/S106193481114019X

Vancouver

Saprygin AV, Elistratov OV, Kalashnikov VA, Kulik IS, Rodichev IA. Mass spectrometry determination of the isotopic composition of uranium hexafluoride. Journal of Analytical Chemistry. 2011;66(14):1385-1391. doi: 10.1134/S106193481114019X

Author

Saprygin, A. V. ; Elistratov, O. V. ; Kalashnikov, V. A. и др. / Mass spectrometry determination of the isotopic composition of uranium hexafluoride. в: Journal of Analytical Chemistry. 2011 ; Том 66, № 14. стр. 1385-1391.

BibTeX

@article{9b3e771f1e434221840bed16f9e58fff,
title = "Mass spectrometry determination of the isotopic composition of uranium hexafluoride",
abstract = "An absolute method for the determination of isotopic composition of substances in multiple collector mass spectrometers was proposed. The detailed analysi of terms used in the method for the determination of the isotopic composition of uranium hexafluoride was given. Parabolic nature of occurring constant measurement error, obtained in theory, was proved by test data for 235U within a wide range of its concentrations. In order to use the method of measurements in practice, the registration of constant error, through linear discriminatory relations Δc i(c i), preliminary determined using uranium hexafluoride with standard isotopic composition, was proposed. The advantages of the developed method in comparison with the traditional analysis procedures, applied at present, were considered. {\textcopyright} Pleiades Publishing, Ltd., 2011.",
author = "Saprygin, {A. V.} and Elistratov, {O. V.} and Kalashnikov, {V. A.} and Kulik, {I. S.} and Rodichev, {I. A.}",
year = "2011",
doi = "10.1134/S106193481114019X",
language = "English",
volume = "66",
pages = "1385--1391",
journal = "Journal of Analytical Chemistry",
issn = "1061-9348",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "14",

}

RIS

TY - JOUR

T1 - Mass spectrometry determination of the isotopic composition of uranium hexafluoride

AU - Saprygin, A. V.

AU - Elistratov, O. V.

AU - Kalashnikov, V. A.

AU - Kulik, I. S.

AU - Rodichev, I. A.

PY - 2011

Y1 - 2011

N2 - An absolute method for the determination of isotopic composition of substances in multiple collector mass spectrometers was proposed. The detailed analysi of terms used in the method for the determination of the isotopic composition of uranium hexafluoride was given. Parabolic nature of occurring constant measurement error, obtained in theory, was proved by test data for 235U within a wide range of its concentrations. In order to use the method of measurements in practice, the registration of constant error, through linear discriminatory relations Δc i(c i), preliminary determined using uranium hexafluoride with standard isotopic composition, was proposed. The advantages of the developed method in comparison with the traditional analysis procedures, applied at present, were considered. © Pleiades Publishing, Ltd., 2011.

AB - An absolute method for the determination of isotopic composition of substances in multiple collector mass spectrometers was proposed. The detailed analysi of terms used in the method for the determination of the isotopic composition of uranium hexafluoride was given. Parabolic nature of occurring constant measurement error, obtained in theory, was proved by test data for 235U within a wide range of its concentrations. In order to use the method of measurements in practice, the registration of constant error, through linear discriminatory relations Δc i(c i), preliminary determined using uranium hexafluoride with standard isotopic composition, was proposed. The advantages of the developed method in comparison with the traditional analysis procedures, applied at present, were considered. © Pleiades Publishing, Ltd., 2011.

UR - https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=tsmetrics&SrcApp=tsm_test&DestApp=WOS_CPL&DestLinkType=FullRecord&KeyUT=000298358800005

UR - http://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=84855671485

U2 - 10.1134/S106193481114019X

DO - 10.1134/S106193481114019X

M3 - Article

VL - 66

SP - 1385

EP - 1391

JO - Journal of Analytical Chemistry

JF - Journal of Analytical Chemistry

SN - 1061-9348

IS - 14

ER -

ID: 37906212