Результаты исследований: Вклад в журнал › Статья › Рецензирование
Результаты исследований: Вклад в журнал › Статья › Рецензирование
}
TY - JOUR
T1 - Heat transfer with a cross flow of steam condensing on vertical tubes
AU - Brodov, Yu. M.
AU - Aronson, K. E.
AU - Ryabchikov, A. Yu.
PY - 1989
Y1 - 1989
N2 - An analysis of the efficiency of power-generating plant heat exchangers under operational conditions reveals the differences between experimental and theoretical data. One of the possible reasons for these differences, in the authors' opinion, is the unimproved method of thermal calculation for heat exchangers, in particular the method of making allowance for velocity of the approach flow. As shown by calculations carried out according to the Guidelines b the zone-by-zone method, in vertical condensing heat exchangers there are zones of condensation for practically stationary steam and zones with high steam velocities.
AB - An analysis of the efficiency of power-generating plant heat exchangers under operational conditions reveals the differences between experimental and theoretical data. One of the possible reasons for these differences, in the authors' opinion, is the unimproved method of thermal calculation for heat exchangers, in particular the method of making allowance for velocity of the approach flow. As shown by calculations carried out according to the Guidelines b the zone-by-zone method, in vertical condensing heat exchangers there are zones of condensation for practically stationary steam and zones with high steam velocities.
UR - http://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=0024667419
M3 - Article
VL - 36
SP - 270
EP - 273
JO - Thermal Engineering (English translation of Teploenergetika)
JF - Thermal Engineering (English translation of Teploenergetika)
SN - 0040-6015
IS - 5
ER -
ID: 52189373