Standard

Experience gained from development of modernized oil coolers for the oil supply system used in 800-MW turbines. / Aronson, K. e.; Brodov, Yu. m.; Ryabchikov, A. yu. и др.
в: Thermal Engineering, Том 56, № 8, 01.08.2009, стр. 636-643.

Результаты исследований: Вклад в журналСтатьяРецензирование

Harvard

APA

Vancouver

Author

BibTeX

@article{1ad58f14391e4daa9cb9322d3df4b85e,
title = "Experience gained from development of modernized oil coolers for the oil supply system used in 800-MW turbines",
abstract = "Problems encountered during retrofitting of oil coolers in operating steam turbine units are discussed. Results obtained from numerical simulation of oil leaks occurring in the gaps between the tube bundles of oil coolers are presented. Different design versions of a modernized MB-270-330 oil cooler are calculated, and the effect of different design parameters on the performance characteristics of such apparatuses is analyzed. The adopted technical solutions made it possible to develop the oil cooler that has been installed in 13 of the 15 800-MW turbine units that are currently in operation in Russia.",
author = "Aronson, {K. e.} and Brodov, {Yu. m.} and Ryabchikov, {A. yu.} and Brezgin, {D. v.} and Brezgin, {V. i.}",
year = "2009",
month = aug,
day = "1",
doi = "10.1134/S0040601509080035",
language = "English",
volume = "56",
pages = "636--643",
journal = "Thermal Engineering",
issn = "0040-6015",
publisher = "Pleiades Publishing",
number = "8",

}

RIS

TY - JOUR

T1 - Experience gained from development of modernized oil coolers for the oil supply system used in 800-MW turbines

AU - Aronson, K. e.

AU - Brodov, Yu. m.

AU - Ryabchikov, A. yu.

AU - Brezgin, D. v.

AU - Brezgin, V. i.

PY - 2009/8/1

Y1 - 2009/8/1

N2 - Problems encountered during retrofitting of oil coolers in operating steam turbine units are discussed. Results obtained from numerical simulation of oil leaks occurring in the gaps between the tube bundles of oil coolers are presented. Different design versions of a modernized MB-270-330 oil cooler are calculated, and the effect of different design parameters on the performance characteristics of such apparatuses is analyzed. The adopted technical solutions made it possible to develop the oil cooler that has been installed in 13 of the 15 800-MW turbine units that are currently in operation in Russia.

AB - Problems encountered during retrofitting of oil coolers in operating steam turbine units are discussed. Results obtained from numerical simulation of oil leaks occurring in the gaps between the tube bundles of oil coolers are presented. Different design versions of a modernized MB-270-330 oil cooler are calculated, and the effect of different design parameters on the performance characteristics of such apparatuses is analyzed. The adopted technical solutions made it possible to develop the oil cooler that has been installed in 13 of the 15 800-MW turbine units that are currently in operation in Russia.

UR - http://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=69249125841

U2 - 10.1134/S0040601509080035

DO - 10.1134/S0040601509080035

M3 - Article

VL - 56

SP - 636

EP - 643

JO - Thermal Engineering

JF - Thermal Engineering

SN - 0040-6015

IS - 8

ER -

ID: 38904480